Replacing a Defective Sensor on Elkay EZH20 Bottle Filling Stations
In this video, we'll show you step-by-step how to remove the defective IR sensor and replace it with a new one. We also show what parts you will need and what tools to use.
Applicable to original Elkay EZH2O models (ending in "K")
EZS8WSLK, LZS8WSLK, EZSTL8WSLK, LZSTL8WSLK, EZS8WSSK, LZS8WSSK, EZSTL8WSSK, LZSTL8WSSK
Enhanced EZH2O models (ending in "P")
LZS8WSLP, LZSTL8WSLP, LZS8WSSP, LZSTL8WSSP
Parts Mentioned:
- 98544C - for original bottle fillers
- 1000002434 - for "Enhanced" bottle fillers
Tools Needed:
- 5/32" Allen Wrench (does not need to be security type)
- 3/8" Socket Wrench (a crescent wrench will not work)
- Philips Head Screwdriver (size "0", PHO)